⭕️API PLAN 02⭕️
✔️Description
Dead ended seal chamber with no flush fluid circulation.
✔️Features
1. Applicable to low seal chamber pressure and process temperature.
2. Can be used with tapered seal chambers, especially for slurries.
3. Normally is used along with a jacketed seal chamber.
✔️Use
1. In cool clean fluids with high specific heat, such as water, in relatively low speed pumps.
✔️Caution
1. To avoid flashing, process fluid temperature must be taken into consideration.
2. Avoid use without cooling / heating jacket (for cylindrical chambers).
3. Ensure top point vent in throat bush (for cylindrical chambers in horizontal pumps).
✨️✨️⬇️🆔️⬇️✨️✨️
@mechanicalseal
#arta_sanat_arsen
#mechanical_seal
#API_PLAN_02
✔️Description
Dead ended seal chamber with no flush fluid circulation.
✔️Features
1. Applicable to low seal chamber pressure and process temperature.
2. Can be used with tapered seal chambers, especially for slurries.
3. Normally is used along with a jacketed seal chamber.
✔️Use
1. In cool clean fluids with high specific heat, such as water, in relatively low speed pumps.
✔️Caution
1. To avoid flashing, process fluid temperature must be taken into consideration.
2. Avoid use without cooling / heating jacket (for cylindrical chambers).
3. Ensure top point vent in throat bush (for cylindrical chambers in horizontal pumps).
✨️✨️⬇️🆔️⬇️✨️✨️